Product Description
50mm metal surface handmade rock wool sandwich panel with MGO adopts color-coated or stainless steel sheet as the surface and the surrounding galvanized steel strips and galvanized corners are sealed, and the rock wool (can be water-proof) is filled with single or double layers of 5mm glass magnesium board  as the inner core layer. Manufactured through processes such as heating, pressing, and curing.
Product Description

Line-Link's Purified Water Generator System is a cutting-edge solution designed to deliver reliable, high-quality purified water. Tailored to meet specific customer needs, the system incorporates advanced optimization features, including an internal circulation design that prevents microbial growth during periods of inactivity, ensuring rapid restarts with minimal downtime. By considering raw water quality and integrating efficient process design, the system achieves up to an 80% water production rate, significantly reducing operational costs. To maintain water purity, flexible sanitization options, such as chemical and hot water sanitization, are available. The modular design, integrating all components into a single independent frame, simplifies installation and saves space. Automatic control with multiple operating modes offers flexibility and ease of use across various applications. The system's comprehensive configuration includes Filtration, softening, ultrafiltration, chemical dosing, reverse osmosis (RO), electrodeionization (EDI), and other modules, according to specific needs. With these innovative features, Line-Link's Purified Water Generator System enhances operational efficiency, reduces energy consumption, and extends system longevity, making it a reliable and cost-effective choice for water treatment. 

Physical Parameters

QUALITY OF PURIFIED WATER

Parameter 

Unit 

USP 

EP 

CP 

TOC 

mg/L 

0.5

0.5

0.5

Conductivity 

µs/cm@ 25°C 

≤1.3 

≤5.1 

≤5.1 

Nitrate(NO3) 

ppm 

– 

≤0.2 

≤0.06 

Heavy Metals 

ppm 

– 

≤0.1 

≤0.1 

Aerobic Bacteria 

CFU/ml 

≤100 

≤100 

≤100